4/18/2023

Facility


TADOUGHS
815 N EIGTH ST
PEKIN, IL 61554
« Back

Related Reports
Date: 07/24/2024

Inspection Type: Regular
5. **** -Facility could not locate procedures regarding bodily fluid clean up. COS. Inspector provided an policy via email. ****
10. **** The back bathroom did not have a sign that notifies employees to wash hands. COS. Inspector is providing a sign to be posted. ****
36. **** Two fridges (both the dairy fridge behind the counter and the back dough fridge) did not have internal thermometers placed inside of them. Please ensure that thermometers are placed within these by next routine inspection. ****
47. **** The upper part of the donut fryer has exposed insulation. Ensure that this insulation is properly sealed to avoid any potential contamination and so that the area is smooth and easily cleanable. ****
55. **** The floor of the back kitchen area has several chips in places and the area where an oven used to be is all exposed flooring. Ensure that the flooring is repaired so that it is smooth and easily cleanable. ****